Modules serve to minimise assembly times on site. They facilitate assembly at the construction site and contribute towards more economical work. Modules / assemblies are manufactured at Hagelschuer’s Buldern plant and delivered to the customer after production control.
flange elbow, 90°, black, DN25 L80 x L80, PN40
Condensate return system 500 l stainless steel
with 2 pumps incl. fittings
Condensate return system 300 l stainless steel
with 2 pumps incl. fittings
Condensate return system 2000 l stainless steel
with 1 pump incl. fittings
Condensate return system 1500 l stainless steel
with 1 pump incl. fittings
Condensate return system 1000 l stainless steel
with 1 pump incl. fittings
Condensate return system 500 l stainless steel
with 1 pump incl. fittings
Condensate return system 300 l stainless steel
with 1 pump incl. fittings
Blowdown flash tank size 800 litres made from black steel with all necessary connections such as inlet for blowdown water, flushing, drainage pipes as well as aeration and venting pipe, drain connection, cooling water addition via thermostat-controlled water inlet incl. water solenoid valve
Manhole cover P265GH, 320/420mm clear nominal diameter, 16 bar/205°C, upright ring 90/15 mm
Manhole cover P265GH, 320/420mm clear nominal diameter, 13 bar/195 °C, upright ring 90/15 mm
Head hole cover P265GH, 220/320 mm clear nominal diameter, 16 bar/205 °C, upright ring 90/15 mm
Head hole cover P265GH, 220/320 mm clear nominal diameter, 13 bar/195 °C, upright ring 90/15 mm
Hand hole cover P265GH, 150/200mm clear nominal diameter, 13 bar/195 °C, conical ring
Hand hole cover P265GH, 115/165 mm clear nominal diameter, 13 bar/195 °C, conical ring
Hand hole cover P265GH, 80/120 mm clear nominal diameter, 16 bar/205 °C, conical ring
Condensate return system 1500 l stainless steel
with 2 pumps incl. fittings
flange elbow, 90°, black, DN40 L104 x L104, PN40
flange elbow, 90°, black, DN50 L126 x L126, PN40
flange elbow, 90°, black, DN65 L149 x L149, PN40
flange elbow, 90°, black, DN80 L174 x L174, PN40
flange elbow, 90°, black, DN100 L219 x L219, PN40
flange elbow, 90°, black, DN125 L247 x L247, PN16
flange elbow, 90°, black, DN150 L286 x L286, PN16
flange elbow, 90°, black, DN20 L71 x L71, PN40
Heat exchanger station 1000 KW heat output up to max. 100 °C flow temperature for 2.5-16.0 bar(g) steam pressure with condensate accumulation control consisting of:
- Standing tube bundle heat exchanger with CE marking according to DGRL and AD 2000 data sheets for condensate-side control with condensate cooling, tube heating bundle made from straight smooth precision tubes incl. insulation painted on the outside
Steam-side fittings comprising:
- Shut-off as motorised or pneumatic shut-off valve with safety function
- Manual shut-off valve
- Dirt trap
- Vacuum breaker
- Venting system
Condensate-side fittings comprising:
- Manual shut-off valve
- Dirt trap
- Motorised or pneumatic control valve for condensate build-up
- Steam trap
- Inspection glass for flow control
Secondary-side fittings comprising:
- PT 100 temperature sensor for temperature measurement
- Safety thermostat
- Where applicable, pressure limiter min. or pressure limiter max.
- Safety valve to prevent impermissible overpressure on the secondary side
Temperature control comprising:
- Switchgear for operating and monitoring the heat exchanger station, switching the shut-off valve with safety device and controlling the condensate build-up, incl. installation and wiring of the 3-point step controller, where applicable integration of the signals pressure limiter min. or max., setpoint adjustment on the industrial controller
- Compl. pre-assembly of the previously described components on a base frame pre-installed ready for connection and pre-wired
Heat exchanger station 600 KW heat output up to max. 100 °C flow temperature for 2.5-16.0 bar(g) steam pressure with condensate accumulation control consisting of:
- Standing tube bundle heat exchanger with CE marking according to DGRL and AD 2000 data sheets for condensate-side control with condensate cooling, tube heating bundle made from straight smooth precision tubes incl. insulation painted on the outside
Steam-side fittings comprising:
- Shut-off as motorised or pneumatic shut-off valve with safety function
- Manual shut-off valve
- Dirt trap
- Vacuum breaker
- Venting system
Condensate-side fittings comprising:
- Manual shut-off valve
- Dirt trap
- Motorised or pneumatic control valve for condensate build-up
- Steam trap
- Inspection glass for flow control
Secondary-side fittings comprising:
- PT 100 temperature sensor for temperature measurement
- Safety thermostat
- Where applicable, pressure limiter min. or pressure limiter max.
- Safety valve to prevent impermissible overpressure on the secondary side
Temperature control comprising:
- Switchgear for operating and monitoring the heat exchanger station, switching the shut-off valve with safety device and controlling the condensate build-up, incl. installation and wiring of the 3-point step controller, where applicable integration of the signals pressure limiter min. or max., setpoint adjustment on the industrial controller
- Compl. pre-assembly of the previously described components on a base frame pre-installed ready for connection and pre-wired
Pressure reducing station for steam up to 2000 kg/h, design parameters = inlet pressure 8 bar(g), outlet pressure 2 bar(g)
The control unit comprises: Pressure gauge kit, shut-off, dirt trap, cyclone steam dryer with drainage, mechanical pressure reducing valve and safety valve ready for connection mounted on a stand construction
***The items steam dryer and safety valve shown in the illustration are not included in the price calculation, prices on request***
Pressure reducing station for steam up to 1000 kg/h, design parameters = inlet pressure 8 bar(g), outlet pressure 2 bar(g)
The control unit comprises: Pressure gauge kit, shut-off, dirt trap, cyclone steam dryer with drainage, mechanical pressure reducing valve and safety valve ready for connection mounted on a stand construction
***The items steam dryer and safety valve shown in the illustration are not included in the price calculation, prices on request***
Pressure reducing station for steam up to 500 kg/h, design parameters = inlet pressure 8 bar(g), outlet pressure 2 bar(g)
The control unit comprises: Pressure gauge kit, shut-off, dirt trap, cyclone steam dryer with drainage, mechanical pressure reducing valve and safety valve ready for connection mounted on a stand construction
***The items steam dryer and safety valve shown in the illustration are not included in the price calculation, prices on request***